DC Solutions · engineering & telemetry
Plan, cost and commission a data center with numbers an engineer would sign.
Twenty-one calculators, seven engines and nine operations cockpits share one method: every figure is computed from a declared basis, carries its registry id, and can be traced to the line that produced it. The plant below is that method, running.
Hover or tap a box to read its rows · double-click or Enter opens the page where it is computed · the bins above play on their own, touch one to hold it
Computed against
ASHRAE TC 9.9TIA-942-CUptime Institute TierNFPA 75 · 76 · 2001 · 855ISO 50001 · 30134EN 50600GHG Protocol01 / The instruments
Every tool, on one page. 41 cockpits, calculators, monitors, labs and papers — each states its basis before it prints a number.
Keyboard: j / k move down the list, Enter opens
CockpitsTwo buildings run as operations cockpits, every number from an engine.
Cost and planningBuild it on paper first.
- A.01CAPEX calculator14 cost components · scenario A vs B · tier classification · PDFOpen↗
- A.02OPEX calculator30+ countries · climate zones · staffing · energy and maintenanceOpen↗
- A.03DC MOCCAPEX + OPEX engine · shift optimisation · Monte Carlo · executive PDFOpen↗
- A.04Cx calculatorL0–L6 commissioning lifecycle · Gantt · Monte Carlo · 8 archetypesOpen↗
- A.05RFS readiness workbenchG0–G7 gate board · defect tracking · customer overlay · forecastOpen↗
- A.06Spares readiness engineCritical spares, lead time and stock-out risk per systemOpen↗
Strategy and marketDecide with the numbers in front of you.
Engineering and complianceSize it, check it, prove it against the standard.
- C.01PUE calculatorCooling type · climate zone · IT load distributionOpen↗
- C.02Tier advisorUptime Tier I–IV · TIA-942 · EN 50600 · 12+ jurisdictionsOpen↗
- C.03TIA-942 checklist56 items · 4 tiers · weighted scoring and gap analysisOpen↗
- C.04Carbon footprintGHG Protocol scope 1/2/3 · life-cycle · 33 countriesOpen↗
- C.05Fire suppression calculatorNFPA 2001 clean-agent sizing · NOAEL marginOpen↗
- C.06Fire safety checklistDetection and suppression design bands · NFPA 855 batteriesOpen↗
- C.07Liquid-cooling CDU toolkitSelection guide · maintenance checklist · mini-BMS · comparisonOpen↗
- C.08Air vs liquid coolingDX · chilled water · RDHx · direct-to-chip for AI/HPC loadsOpen↗
- C.09Raised floor vs slabPlenum vs overhead · load capacity · retrofit costOpen↗
Grid monitorsWhere the power is, region by region.
LabsThe methods behind the numbers, as workbenches you can run.
- L.01Standards + liquid-to-chip labANSI/TIA-942 · ASHRAE TC 9.9 · ISO 50001 · NFPA · Uptime enginesOpen↗
- L.02Liquid-to-chip system modelling labCDU · manifold · chip stack · acceptance · DH01 CFDOpen↗
- L.03Network visualization hubModbus · BACnet · OPC-UA · DNP3 · PROFINET · TLS · APIs, animatedOpen↗
- L.04AI engineering maintenanceFMECA + knowledge graph · 109 fault modes · ML advisor conceptOpen↗
KnowledgePapers, pillars, manuals, incidents.
- P.01Data center power distribution designTechnical paper · hyperscaler architecture, 2026Open↗
- P.02Cooling systemsAir · chilled water · direct liquid · free cooling · PUEOpen↗
- P.03Power systemsUPS · generators · switchgear · PDU · N+1 · grid connectionOpen↗
- P.04Fire safetyNFPA 75/76 · VESDA · clean agent · compartmentationOpen↗
- P.05SustainabilityPUE · WUE · CUE · ERF · REF · ISO/IEC 30134 · worked exampleOpen↗
- P.06Incident library43 dossiers · sequence of events · FMEA · role-by-role responseOpen↗
- P.07Technical manualsFormulas and methodology for every engine on this siteOpen↗
02 / The hardware
The rack the plant is built from. GB300 NVL72 — 72 GPUs in one NVLink domain, 142 kW, drawn from the published counts. Drag it, open it.
Counts are PUBLISHED (DGX GB300 reference architecture, nvidia.com); the frame, tray pitch, stacking order and the placement of parts inside a tray are ADOPTED from Open Rack v3 and NVIDIA photographs — no public CAD exists, and nothing here claims to be one.
03 / Who
Built by a certified data-center engineer. Not a content team.
Bagus Dwi Permana leads engineering operations for mission-critical facilities in Bekasi, Indonesia. The site is his working method, published: the same checks he runs before a switching order are the gates every page here passes before it ships.
CDCP · CDCS · ATD · ATS
ISO 50001 lead auditor
Profile and record →
04 / Questions
Where do the numbers on this page come from?
From js/dcai-engine.js, the DC AI engine, computed in your browser from a declared model (js/dcai-model.js). Every value carries a registry id; the readout beside the drawing prints it.
Is the 500 MW campus a real site?
No. It is an adopted GB300 scenario — simulated, not measured telemetry — built so that every count is derived and every check can fail. The engine says so in its own metadata.
Do I need an account?
The calculators, grid monitors, manuals and the journal are open. The two operations cockpits and the labs ask for a sign-in because they carry the full model.
Can I export?
Every calculator exports CSV; the cockpits export a Tech Spec PDF; the labs export the engineering report.